序号 NO. |
常见故障表现 Common faults |
故障可能因素 Possible factors for malfunction |
解决方案 Solution |
1 |
粪道清理不干净,表面有剩余牛粪 The manure passage is not cleaned thoroughly, and there is residual manure on the passage. |
和地面接触的耐磨橡胶条磨损严重 Severe wear of wear-resistant rubber strips in contact with the ground |
橡胶条下移调整,或联系厂家更换。 定期检查橡胶条磨损情况 Move the rubber strip downward, or contact the manufacturer for replacement. Regularly check the wear of rubber strips |
2 |
刮板回退过程中,升起高度过低,造成带粪回退。 During the process of retracting the scraper, the lifting height was too low, causing retreat with manure. |
刮板长期运行,耐磨脚磨损严重,造成刮板回退过程中支起高度过低。 The scraper operates for a long time, and the wear-resistant feet are severely worn, causing the height of the support too low during the scraper retraction. |
联系厂家更换耐磨脚。 定期检查维护。 Contact the manufacturer to replace the wear-resistant feet. Regular inspection and maintenance. |
3 |
代码:E.ocA 加速运行过流 Code: E.ocA Overcurrent during accelerated operation |
排查转角轮或链条有异物卡住,造成过载停机保护。 电机或减速机损坏。 Check if there are foreign objects stuck in the corner wheel or chain, which causing overload and shutdown protection. The motor or reducer is damaged |
排查各部位并清除异物。 维修或更换电机减速机。 Inspect all parts and remove foreign objects. Repair or replace the motor reducer. |
4 |
代码:E.ocb 启动瞬间过流 Code: E.ocb Instantaneous overcurrent during startup |
||
5 |
代码:E.ocn 恒速运行过流 Code: E.ocn Overcurrent during constant speed operation |
||
6 |
代码:AE.DCL 直流母线欠压 Code: AE DCL DC bus under voltage |
配电电源或输入、输出电缆有故障。 There is fault in the distribution power supply or input/output cables. |
专业人员检修配电电源; 检查并更换控制箱的输入电缆或输出电缆。 Professional personnel inspect and repair the distribution power supply; Check and replace the input or output cables of the control box. |
7 |
代码:AE.PLI 电源输入缺相 Code: AE PLI Power input phase loss |
||
8 |
代码:AE.PLO 电机输出缺相 Code: AE PLO Motor output phase loss |
||
9 |
代码:E.HR1 U相传感器异常 Code: E HR1 Abnormal U-phase sensor |
变频模块损坏 The frequency conversion module is damaged |
联系厂家维修或更换 Contact the manufacturer for repair or replacement |
10 |
代码:E.HR2 V相传感器异常 Code: E HR2 Abnormal V-phase sensor |
||
11 |
代码:EFOP 逆变模块保护 Code: EFOP Inverter module protection |
||
12 |
代码:EOHI 散热器过热 Code: EOHI heatsink overheat |
控制箱所处环境温度过高; 灰尘或异物阻塞散热孔,导致散热器通风不良 The ambient temperature of the control box is too high; Dust or foreign objects blocking the heat dissipation holes, resulting in poor ventilation of the radiator.
|
更换控制箱安装位置; 改善散热器通风状况。 Replace the installation position of the control box; Improve the ventilation of the radiator. |
13 |
AE.CFE 通讯异常 Code: AE CFE Communication abnormality |
显示屏与主板间通讯线插头松动; 显示屏损坏 Loose communication cable plug between display screen and motherboard; Damaged display screen |
检查通讯线插头; 联系厂家更换显示屏。 Check the communication cable plug; Contact the manufacturer to replace the display screen. |