内容说明

序号

Item

常见故障表现

Common faults

故障可能因素

Possible factors for faults

解决方案

Solution

1

个别喷头非正常喷水,或停止喷淋后个别喷头还在喷水

Some nozzles spray water abnormally, or some nozzles still spray water after stop spraying

喷头内有异物

Foreign objects inside the nozzle

清理喷头内异物

Clean foreign objects inside the nozzle

2

喷淋启动后,其中一路喷水压力较小

After startup, one of the water spray pressures is relatively low

过滤器滤网堵塞;

或管线堵塞。

Filter screen clogged;

Or pipeline blocked

定期清理过滤器;

检查清理管线

Regularly clean the filter;

Inspect and clean the pipeline

3

水泵启动后不停,压力数值达不到设定压力

The pump can not stop after startup, and the pressure cannot reach the set pressure.

储水箱内水位过低;

水泵腔体可能进气

The water level in the water storage tank is too low;

The water pump chamber may be filled with air.

做好水源管理

参见说明书,排出水泵内气体。

Properly manage the water sources;

Refer to the manual and discharge the gas inside the water pump.

4

环境温度未达到设定温度喷淋启动

The ambient temperature has not reached the set temperature, but the spray started

温度未校准;

温度感应探头损坏

Temperature not calibrated;

Temperature sensing probe damaged

参见说明书,校准温度数值;

如果温度感应探头损坏,联系厂家更换。

Refer to the manual to calibrate the temperature values;

If the temperature sensing probe is damaged, contact the manufacturer for replacement.

5

环境温度超过设定温度,喷淋不启动。

Ambient temperature exceeds the set temperature, but the spray does not start.

6

电磁阀不能正常打开

The solenoid valve cannot open normally

控制箱中变压器损坏

The transformer in the control box is damaged

测量控制箱是否有AC24V输出,如无输出,请联系厂家更换变压器。

Check if the control box has AC 24V output. If there is no output, please contact the manufacturer to replace the transformer

电磁阀损坏

Solenoid valve damaged

测量控制箱中是否有AC24V输出,如有输出,请联系厂家更换电磁阀(或电磁头)Measure if there is AC 24V output in the control box. If there is an output, please contact the manufacturer to replace the solenoid valve (or solenoid head)